CFW-09 - QUICK PARAMETER REFERENCE
32
Parameters Function Adjustable Range
Factory
Unit
User's
Page
Setting Setting
P527 PIDAction 0 = Direct 0 = Direct - 224
1 = Reverse
P528 Process Variable Scale Factor 0 to 9999 1000 - 225
P529 Decimal Point of Proc. Var. 0 to 3 1 225
P530 Engineering Unit of Proc. Var. 1 32 to 127 (ASCII) 37 = % - 226
A, B, ... , Y, Z
0, 1, ... , 9
#, $, %, (, ), *, +, ...
P531 Engineering Unit of Proc. Var. 2 32 to 127 (ASCII) 32 = blank - 226
A, B, ... , Y, Z
0, 1, ... , 9
#, $, %, (, ), *, +, ...
P532 Engineering Unit of Proc. Var. 3 32 to 127 (ASCII) 32 = blank - 226
A, B, ... , Y, Z
0, 1, ... , 9
#, $, %, (, ), *, +, ...
P533 Value of Proc. Var. X 0.0 to 100 90.0 % 226
P534 Value of Proc. Var. Y 0.0 to 100 10.0 % 226
P535 Wake Up Band 0 to 100 0 % 227
P536
(1)
Automatic Setting of P525 0 = Active 0 = Active - 227
1 = Inactive
P537 Hysteresis for Set point = 1 to 100 1 % 227
Process Variable
P538 Hysteresis for VPx/VPy 0.0 to 50.0 1.0 % 227
Notes presented on Quick Parameter Description:
(1) Parameter can be changed only with the inverter disabled (motor stopped).
(2) Values may change as a function of the “Motor Parameters”.
(3) Values may change as a function of P413 (Tm Constant - obtained during
Self-tuning).
(4) Values may change as a function of P409 and P411 (obtained during Self-
tuning).
(5) Values may change as a function of P412 (Tr Constant - obtained during
Self-tuning).
(6) Values may change as a function of P296.
(7) Values may change as a function of P295.
(8) Values may change as a function of P203.
(9) Values may change as a function of P320.
(10) User’s Standard (for new inverters) = without parameter.
(11) The inverter will be delivered with settings according to the market,
considering the HMI language, V/F 50 Hz or 60 Hz and the required voltage.
The reset of the standard factory setting may change the parameters related
to the frequency (50 Hz/60 Hz). Values within parenthesis mean the factory
setting for 50 Hz.
(12) The maximum value of P156 and P401 is 1.8 x P295 for model 4.2 A/500-
600 V and 1.6 x P295 for models 7 A and 54 A/220-230 V; 2.9 A and 7 A/500-
600 V; 107 A, 147 A and 247 A/500-690 V; 100 A, 127 A and 340 A/660-690 V.
coin