WEG CFW-09 User Manual Page 155

  • Download
  • Add to my manuals
  • Print
  • Page
    / 362
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 154
156
CHAPTER 6 - DETAILED PARAMETER DESCRIPTION
P224
(1)
0 to 4
LOCALSTART/STOP [ 0 ]
Selection -
Note: If the Digital Inputs are programmed for Forward Run/Reverse
Run, the and keys will remain disabled independently of the
value programmed at P224.
P225
(1) (8)
0 to 5
LOCAL JOG [ 1 ]
Selection -
The JOG speed reference is given by parameter P122.
Range
[Factory Setting]
Parameter Unit Description / Notes
P223
(1) (8)
0 to 11
LOCAL FWD/REV [ 2 ]
Selection -
Table 6.27 - LOCAL FWD/REV selection
Table 6.28 - LOCAL START/STOP selection
Table 6.29 - LOCAL JOG selection
P223
0
1
2
3
4
5
6
7
8
9
10
11
LOCAL FWD/REV Selection
Always Forward
Always Reverse
Key of the Keypad (Default Forward)
Key of the Keypad (Reverse Default)
Digital Input DI2 (P264 = 0)
Serial (FWD Default)
Reserved Serial (REV Default)
Fieldbus (FWD Default)
Fieldbus (REV Default)
Polarity AI4
PLC (FWD)
PLC (REV)
LOCAL START/STOP Selection
and of the Keypad
Digital Input (DIx)
Serial
Fieldbus
PLC
P224
0
1
2
3
4
P225
0
1
2
3
4
5
LOCAL JOG Selection
Disable
Key of the Keypad
Digital inputs DI3 to DI8 (P265 to P270)
Serial
Fieldbus
PLC