Referencia Rápida de los Parámetros, Alarmas y Fallas
Español
40 | MW500
Parám. Descripción
Rango de
Valores
Ajuste de
Fábrica
Ajuste
del
Usuario
Prop. Grupos
P0271 Señal de las DIs 0 = Todas DIx son NPN
1 = DI1 - PNP
2 = (DI1...DI2) PNP
3 = (DI1...DI3) PNP
4 = (DI1...DI4) PNP
5 = (DI1...DI5) PNP
6 = (DI1...DI6) PNP
7 = (DI1...DI7) PNP
8 = Todas DIx son PNP
0 cfg I/O
P0275 Función de la Salida DO1 0 = Sin Función
1 = F* > Fx
2 = F > Fx
3 = F < Fx
4 = F = F*
5 = Sin Función
6 = Is > Ix
7 = Is < Ix
8 = Torque > Tx
9 = Torque < Tx
10 = Remoto
11 = Run
12 = Ready
13 = Sin Falla
14 = Sin F0070
15 = Sin Función
16 = Sin F0021/22
17 = Sin Función
18 = Sin F0072
19 = 4-20 mA OK
20 = Contenido P0695
21 = Sent. Horario
22 = V. Proc. > VPx
23 = V. Proc. < VPx
24 = Ride-Through
25 = Precarga OK
26 = Con Falla
27 = Sin Función
28 = SoftPLC
29 a 34 = Sin Función
35 = Sin Alarma
36 = Sin Falla/Alarma
37 = Función 1 Aplicación
38 = Función 2 Aplicación
39 = Función 3 Aplicación
40 = Función 4 Aplicación
41 = Función 5 Aplicación
42 = Función 6 Aplicación
43 = Función 7 Aplicación
44 = Función 8 Aplicación
13 I/O
P0276 Función de la Salida DO2 Ver opciones en P0275 2 I/O
P0277 Función de la Salida DO3 Ver opciones en P0275 0 I/O
P0278 Función de la Salida DO4 Ver opciones en P0275 0 I/O
P0279 Función de la Salida DO5 Ver opciones en P0275 0 I/O
P0287 Histéresis Fx 0.0 a 500.0 Hz 0.5 Hz I/O
P0288 Velocidad Fx 0.0 a 500.0 Hz 3.0 Hz I/O
P0290 Corriente Ix 0.0 a 200.0 A 1.0xI
nom
I/O
P0293 Torque Tx 0 a 200 % 100 % I/O