Page view 12
Quick Reference of Parameters, Alarms and Faults
English
14 | MW500
Param.
Description
Adjustable
Range
Factory
Setting
User
Setting
Properties Groups
P0271 DIs Signal 0 = All DIx are NPN
1 = DI1-PNP
2 = (DI1...DI2) PNP
3 = (DI1...DI3) PNP
4 = (DI1...DI4) PNP
5 = (DI1...DI5) PNP
6 = (DI1...DI6) PNP
7 = (DI1...DI7) PNP
8 = All DIx are PNP
0 cfg I/O
P0275 DO1 Output Function 0 = Not Used
1 = F* > Fx
2 = F > Fx
3 = F < Fx
4 = F = F*
5 = Not Used
6 = Is > Ix
7 = Is < Ix
8 = Torque > Tx
9 = Torque < Tx
10 = Remote
11 = Run
12 = Ready
13 = No Fault
14 = No F0070
15 = Not Used
16 = No F0021/22
17 = Not Used
18 = No F0072
19 = 4-20 mA OK
20 = P0695 Value
21 = Forward
22 = Proc. V. > VPx
23 = Proc. V. < VPx
24 = Ride-Through
25 = Pre-Charge OK
26 = Fault
27 = Not Used
28 = SoftPLC
29 to 34 = Not Used
35 = No Alarm
36 = No Fault/Alarm
37 = Function 1 Application
38 = Function 2 Application
39 = Function 3 Application
40 = Function 4 Application
41 = Function 5 Application
42 = Function 6 Application
43 = Function 7 Application
44 = Function 8 Application
13 I/O
P0276 DO2 Function See options in P0275 2 I/O
P0277 DO3 Function See options in P0275 0 I/O
P0278 DO4 Function See options in P0275 0 I/O
P0279 DO5 Function See options in P0275 0 I/O
P0287 Fx Hysteresis 0.0 to 500.0 Hz 0.5 Hz I/O
P0288 Fx Speed 0.0 to 500.0 Hz 3.0 Hz I/O
P0290 Ix Current 0.0 to 200.0 A 1.0xI
nom
I/O
P0293 Tx Torque 0 to 200 % 100 % I/O
P0295 VFD Rated Curr. 0.0 to 200.0 A According to
inverter model
ro READ