MW500 - MotorDrive12
Plug-In Modules Specification
3)
Notes: 1) Optional: hardware resources added to the MW500 in the manufacturing process accessory = hardware resource requested as a separated item.
2) Request the product according to the code available on page 10.
3) All models of plug-in modules have at least one RS485 port. The CRS485 plug-in module has two RS485 ports. The MW500 allows installing one
plug-in module per unit.
Plug-in module
Functions
Inputs Outputs
USB port
Fieldbus networks Power supply
Digital Analog Analog Digital relay
Digital
transistor
CANopen/
DeviceNet
RS232 RS485 Profibus-DP 10 V 24 V
IOS 4 1 1 1 1 - - - 1 - 1 1
IOD 8 1 1 1 4 - - - 1 - 1 1
IOAD 6 3 2 1 3 - - - 1 - 1 1
IOR 5 1 1 4 1 - - - 1 - 1 1
CUSB 4 1 1 1 1 1 - - 1 - 1 1
CCAN 2 1 1 1 1 - 1 - 1 - 1 1
CRS232 2 1 1 1 1 - - 1 1 - - 1
CRS485 4 2 1 2 1 - - - 2 - 1 1
CPDP 2 1 1 1 1 - - - 1 1 - 1
Accessories and Optionals
The MW500 VSD was developed to meet the hardware configurations required by a wide range of
applications. The table below presents the available options:
2 - Insert accessory
Simple!
1 - Remove cover 3 - Close cover
Step by Step
Option Type
1)
Description Optional item code
2)
Accessory model Available
RFI filter Optional
Used to reduce the disturbance conducted from the
CFW500 to the power supply, in the high frequency
band (>150 kHz), according to standards
61800-3 and EN 55011
C2 or C3 -
Factory installation
only
Braking IGBT Optional
Used in high-inertia applications for the fast stop of
the motor by means of an external braking resistance.
Resistance not included. For the calculation of the
braking resistance, refer to the MW500 user manual
DB -
Factory installation
only
Disconnect switch Optional
A disconnect switch built-in the product for easy
and safe maintenance. This optional makes the
VSD IP65
DS -
Factory installation
only
Wall mounting kit Accessory
An adaptation plate for assemble the drive on the wall
For more information please check the user manual
- MW500 - KCFB User installation
Motor mounting kit Accessory
An adaptation box for assemble the drive on the motor.
For more information please check the user manual
-
MW500 - KAIM - A55
MW500 - KAIM - B56
MW500 - KAIM - B70
User installation
I/O expansion modules
(plug-in)
3)
Accessory
Used to configure the I/O points according
to the needs of the application/machine
-
CFW500-IOS
CFW500-IOD
CFW500-IOAD
CFW500-IOR
-
Communication module
(plug-in)
3)
Accessory
Used for the communication of the MW500 with
the main networks of the market (fieldbus)
-
CFW500-CUSB (USB)
CFW500-CCAN
(CANopen /DeviceNet)
CFW500-CRS232
CFW500-CRS485
CFW500-CPDP (Profibus-DP)
-
Flash memory module
(plug-in)
3)
Accessory
Used to download the programming of a MW500 to
others without having to power them up
- CFW500-MMF -
Remote HMI Accessory
Used to transfer the operation to the panel door
or machine console. Maximum distance of 10 m.
Degree of protection IP54
- CFW500-HMIR -
Cables for remote HMI Accessory
Special cable desing using M8-DB9 connector with
0.5 m, or using the same cables of CFW the MW500
to the remote HMI (CFW500-HMIR)
-
MW500-CCHMIR0.5M
CFW500-CCHMIRXM, where
cables with lengths (X) of 1, 2,
3, 5, 7.5 and 10 meters
-